Description

Louvers and slats are fixed or adjustable external shading elements designed to control direct solar radiation before it reaches windows and building façades.

By reducing solar exposure, they can lower heat gains, improve indoor thermal comfort and reduce cooling demand during heatwaves while maintaining daylight, ventilation and outward views when properly designed.

Image

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy

Implementation Guide

  • Assess façade orientation, solar exposure and overheating risk
  • Select horizontal, vertical or inclined louvers according to solar geometry
  • Define spacing, depth and angle to achieve the required seasonal shading
  • Select materials according to durability, weight and maintenance requirements
  • Verify wind loads, fixing systems and corrosion protection
  • Coordinate shading with daylight and natural ventilation strategies

Benefits and Limitations

Benefits

  • Reduces solar heat gains before they reach the building envelope
  • Improves indoor thermal comfort and cooling performance
  • Provides daylight and glare control
  • Operates passively in fixed configurations
  • Suitable for new construction and retrofit

Limitations

  • Performance depends strongly on orientation and geometry
  • Fixed systems cannot fully adapt to changing conditions
  • Operable systems increase cost and maintenance
  • Poor design can reduce daylight or obstruct views
  • Large systems require adequate structural support

Parameter and data

Design External shading system designed according to façade orientation, solar angles and required seasonal performance

Horizontal louvers are typically more effective where high-angle solar radiation dominates, while vertical fins can provide better control of low-angle solar exposure

Final geometry should be determined through project-specific solar analysis

Materials and Components

  • Aluminium
  • Galvanized or stainless steel
  • Timber or engineered wood
  • PVC
  • Terracotta or ceramic elements
  • Structural brackets and fixings
  • Tracks, pivots or actuators in operable systems
  • Application Façades, windows, curtain walls, balconies, courtyards, roofs and other highly solar-exposed building elements

Technical Properties Typical weight ranges vary according to material:

  • PVC: Approximately 2–10 kg/m²
  • Aluminium: Approximately 5–20 kg/m²
  • Wood: Approximately 8–25 kg/m²
  • Ceramic: Approximately 25–60 kg/m²

Relevant design properties include: Solar shading, glare control, daylight modulation, wind resistance, weather durability and natural-ventilation compatibility

Thermal / Cooling Performance Louvers can significantly reduce solar heat gains when correctly designed

  • Solar heat-gain reduction: Approximately 30–80%
  • Direct solar-radiation blocking: Approximately 40–90%

Actual performance depends on orientation, louver spacing, depth, angle, façade geometry and operating strategy

Operation Passive or adjustable, fixed, manually adjustable or electrically operated

Advantages Durable and flexible solar-control solution that can substantially reduce façade heat gains while maintaining daylight, ventilation and architectural integration

Applicability Criteria Suitable for façades and openings with significant direct solar exposure

The orientation and geometry of the system should be designed according to solar angles rather than applying a single louver configuration to all façades

Operable systems are most appropriate where changing seasonal or daily solar conditions justify additional complexity

Expected Service Life Indicative service lives depend strongly on material:
PVC: approximately 10–20 years
Wood: approximately 15–30 years
Aluminium: approximately 30–50 years
Ceramic: approximately 40–60+ years

Movable mechanisms and actuators may require earlier replacement than the main shading elements