Description

High-performance glazing system selected according to thermal insulation, solar-control and daylight requirements

For heatwave resilience, low emissivity should be combined with an appropriate SHGC/g-value, particularly on highly solar-exposed façades

Image

Default

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy

Implementation Guide

  • Assess façade orientation, glazing ratio and overheating risk
  • Select glazing according to U-value, SHGC/g-value and visible light transmission
  • Combine low-e coatings with solar-control properties where summer overheating is significant
  • Use double or triple insulated glazing units where appropriate
  • Coordinate glazing performance with external shading and façade design
  • Verify glare, daylight and condensation performance

Benefits and Limitations

Benefits

  • Reduces radiant heat transfer through glazing
  • Can reduce solar heat gains when combined with low g-value glazing
  • Improves thermal comfort and cooling performance
  • Maintains daylight and outward views
  • Provides long service life with low maintenance

Limitations

  • Higher cost than conventional glazing
  • Low-e coating alone may not adequately prevent overheating
  • Solar-control performance depends on the selected SHGC/g-value
  • Replacement glazing has a higher embodied impact than simpler retrofit measures
  • Excessive solar control may reduce useful winter gains or daylight

Parameter and data

Design: High-performance glazing system selected according to thermal insulation, solar-control and daylight requirements. For heatwave resilience, low emissivity should be combined with an appropriate SHGC/g-value, particularly on highly solar-exposed façades

Materials and Components:

  • Float glass
  • Low-emissivity metallic or metal-oxide coating
  • Double or triple insulated glazing units
  • Argon or krypton gas fill where applicable
  • Warm-edge spacers
  • Edge seals
  • Solar-control coating where required

Application: Windows, curtain walls, skylights, glazed façades and atria in residential, commercial and public buildings

Technical Properties:

  • Double IGU: Approximately 24–32 mm
  • Triple IGU: Approximately 36–50+ mm
  • Weight: Approximately 20–50 kg/m², depending on glass thickness and number of panes

Thermal / Cooling Performance: Provides medium–high reduction of heat transfer through glazed envelope elements when an appropriate low SHGC/g-value is selected. Performance depends on glazing orientation, solar-control properties, façade area, shading and the characteristics of the complete façade system

Operation: Passive, no operational energy input is required

Advantages: Combines thermal insulation, solar-control potential, daylight transmission and long service life within a conventional glazing system

Maintenance: Low: Standard glass cleaning and periodic inspection of glazing seals, spacers and condensation-related issues

Environmental Impact: Medium: Long service life and reduced operational energy can provide lifecycle benefits, although glass production and complete glazing replacement involve significant embodied impacts

Applicability Criteria: Suitable for glazed façades, windows and skylights where reduction of heat transfer and solar gains is required. For heatwave-prone buildings, the glazing should be selected according to both emissivity and SHGC/g-value, rather than specifying low-e performance alone. External shading should be considered where solar exposure is particularly high

Expected Service Life: 20–30+ years, depending primarily on insulated-glazing-unit seal durability and environmental exposure