Description
Passive design uses building orientation, form, solar protection, natural ventilation, daylight control and thermal mass to reduce overheating without relying primarily on mechanical cooling.
During heatwaves, the strategy aims to limit unwanted solar gains, promote effective air movement and night-time heat release, and maintain useful daylight while minimizing glare and excessive heat transmission.
Image

Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:
Implementation Guide
- Assess local climate, solar exposure, prevailing winds and urban obstructions
- Orient and size openings to control solar gains and daylight
- Provide cross-ventilation and stack-ventilation paths where appropriate
- Prioritize external shading on highly exposed openings
- Use thermal mass only where stored heat can be released effectively
- Validate the strategy through solar, daylight and overheating simulations
Benefits and Limitations
Benefits
- Can substantially reduce overheating and cooling demand
- Requires little operational energy
- Improves thermal comfort and daylight quality
- Increases resilience during power interruptions
- Compatible with most other heatwave adaptation measures
Limitations
- Performance depends strongly on climate and building orientation
- Requires appropriate occupant or automated operation
- Retrofit opportunities may be limited by existing geometry
- Natural ventilation may introduce noise, pollution, security or humidity issues
- Thermal mass can increase overheating if stored heat cannot be released
Parameter and data
Design Integrated passive strategy combining optimized orientation, controlled solar exposure, natural ventilation, daylight management and thermal mass
The design should prioritize reduction of heat gains before relying on mechanical cooling and should be verified under representative summer and heatwave conditions
Materials and Components
Depending on the selected strategy:
Operable windows
External shading devices
Louvers and balconies
Light-coloured finishes
High-performance envelope materials
Concrete, masonry or earthen thermal mass where appropriate
Courtyards, atria or ventilation shafts
Automated windows or controls where required
Application New buildings and retrofits, including residential, educational, office, healthcare, cultural and mixed-use buildings
Technical Properties
Relevant design parameters include:
Window-to-wall ratio adapted to orientation
External shading geometry based on solar angles
Openings positioned to create effective airflow paths
Continuous insulation and airtightness
Thermal mass coordinated with night-time heat release
Daylight control and glare management
Specific numerical values should be defined according to climate and project geometry rather than applied universally
Thermal / Cooling Performance Can substantially reduce cooling loads when orientation, external shading, natural ventilation and night purge are correctly combined
Actual performance is highly project- and climate-dependent and should be assessed through dynamic overheating simulation
Operation Passive, user-controlled or hybrid, some strategies may operate entirely passively, while operable windows, blinds or ventilation openings can also be manually or automatically controlled through BMS logic
Advantages Addresses overheating through the fundamental architecture of the building, reducing dependence on active cooling while simultaneously improving daylight, ventilation and resilience
Applicability Criteria Applicable to both new construction and retrofit, but most effective when incorporated from early design stages
Particularly suitable where orientation, façade geometry, shading and ventilation paths can be optimized together
Natural ventilation strategies should consider outdoor temperature, noise, pollution, humidity, security and fire-safety constraints
Expected Service Life Typically 50+ years, corresponding broadly to the primary building envelope and structural systems
Operable windows, shading mechanisms and automated controls may require earlier maintenance or replacement
Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:

