Description

Vacuum Insulation Panels (VIPs) are high-performance insulation elements composed of a porous core sealed within a gas-tight envelope and evacuated to very low pressure.

Their extremely low thermal conductivity provides high thermal resistance with minimal thickness, making them particularly suitable for heatwave adaptation where space is limited, such as heritage retrofits, roof terraces, window reveals, balconies and compact façade assemblies.

Image

Default

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy

Implementation Guide

  • Use VIPs where limited available thickness justifies their higher cost and detailing requirements
  • Define panel dimensions and layout before installation, as panels cannot normally be cut or penetrated on site
  • Protect panels from mechanical damage during transport, installation and service
  • Coordinate fixings and services to avoid puncturing the vacuum envelope
  • Minimize and calculate thermal bridges at panel edges and joints
  • Use protective boards or prefabricated cassette systems where appropriate

Benefits and Limitations

Benefits

  • Provides very high thermal resistance with minimal thickness
  • Reduces conductive heat gains through the building envelope
  • Particularly useful for constrained retrofit and heritage applications
  • Can effectively address areas where conventional insulation thickness is not feasible
  • Requires little maintenance once correctly protected

Limitations

  • High initial cost
  • Performance can be severely reduced if the vacuum envelope is punctured
  • Panels cannot normally be cut or adapted on site
  • Edge and joint thermal bridges reduce overall system performance
  • Requires precise design, installation and mechanical protection

Parameter and data

Design: High-performance insulation system based on factory-sized vacuum panels arranged to provide maximum continuity while minimizing joints and thermal bridges. Panel layout, fixing points, penetrations and service routes should be coordinated before installation because the vacuum envelope must remain intact

Materials and Components:

  • Fumed silica, glass fibre or similar porous core
  • Gas-tight multilayer barrier envelope
  • Metallized barrier layers
  • Desiccants or getters
  • Protective boards or cassette systems where required
  • Conventional insulation at irregular junctions where VIPs cannot be installed

Application: Façades, roofs, terraces, floors, internal insulation, window reveals, thermal-bridge correction, heritage retrofits and prefabricated façade systems where available construction thickness is limited

Technical Properties:

  • Thermal conductivity: initial centre-of-panel values commonly around 0.004–0.008 W/m·K
  • However, aged/design thermal conductivity is higher and should be taken from the specific product documentation
  • Thickness: typically 10–50 mm
  • Weight: approximately 2–12 kg/m², depending on panel thickness and core material

Thermal / Cooling Performance: Provides very high resistance to conductive heat transfer with limited envelope thickness. Heatwave performance depends on the effective thermal resistance of the complete assembly, including panel ageing, edge effects, joints and thermal bridges. VIPs reduce heat gains but do not provide active cooling or solar protection

Operation: Passive: no operational energy input is required

Advantages: Extremely high thermal performance per unit thickness, making VIPs particularly valuable where conventional insulation cannot achieve the required performance within the available space

Maintenance :Low–Medium: limited routine maintenance once panels are enclosed and protected. Protective layers should be inspected, and future drilling, fixings or renovation works must avoid damaging the vacuum envelope

Environmental Impact: Medium: the very low material thickness can reduce overall envelope volume, but VIPs use specialized multilayer materials and manufacturing processes and are more complex to separate and recycle than conventional insulation

Applicability Criteria: Most appropriate where space constraints are a primary design limitation, such as heritage buildings, window reveals, balconies, terraces and compact retrofit assemblies. Less appropriate where conventional insulation can provide equivalent overall thermal performance without significant space constraints, due to the higher cost and greater installation sensitivity of VIPs

Expected Service Life: 25–50 years, provided that the vacuum envelope remains intact and the panels are protected from mechanical damage. Thermal performance should be assessed using aged/design values rather than initial centre-of-panel conductivity