Description
A ventilated façade is a rainscreen envelope system composed of an external cladding layer separated from the insulated backing wall by a continuous ventilated air cavity.
Solar radiation heats the outer cladding, while wind- and buoyancy-driven airflow within the cavity removes part of this heat before it reaches the primary building envelope. During heatwaves, the system can reduce heat transfer through the façade while protecting insulation and waterproofing layers.
Image

Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:
Implementation Guide
- Assess façade orientation, solar exposure, wind and fire-safety requirements
- Design a continuous ventilated cavity with unobstructed air inlets and outlets
- Maintain continuous insulation and minimize thermal bridges through the substructure
- Select durable cladding according to solar exposure and maintenance requirements
- Provide drainage, cavity barriers and fire stops where required
- Inspect joints, fixings and ventilation openings periodically
Benefits and Limitations
Benefits
- Reduces solar heat transfer through the façade
- Protects insulation and the primary envelope from weather exposure
- Improves moisture management and envelope durability
- Operates passively with low energy demand
- Suitable for both new construction and retrofit
Limitations
- Higher cost and façade depth than direct-applied systems
- Performance depends on cavity continuity and cladding properties
- Fire-safety detailing is critical
- Substructures can create thermal bridges
- Blocked or poorly ventilated cavities reduce performance
Parameter and data
Design Rainscreen façade composed of external cladding, a ventilated air cavity and a continuous insulated backing wall
The cavity should allow effective airflow while maintaining drainage, fire compartmentation and protection of the primary façade
Materials and Components
- Ceramic or terracotta cladding
- Fibre-cement panels
- Metal panels
- Stone
- Timber
- GRC or recycled composite panels
- Mineral wool or bio-based insulation
- Aluminium or steel substructure
- Cavity barriers and fire stops
- Insect mesh and drainage components where required
Application External walls of residential, office, educational, healthcare and public buildings, for both new construction and retrofit projects
Technical Properties
- Insulation thickness: Typically 80–200 mm, depending on the required thermal performance
- Ventilated cavity depth: Typically 40–100 mm, although larger cavities may be used according to façade geometry and ventilation requirements
- Cladding thickness: Approximately 6–40 mm, depending on material and structural requirements
- Overall system thickness: Approximately 150–350 mm
- System weight: Approximately 30–120 kg/m², depending mainly on cladding material, substructure and insulation
- Insulation thermal conductivity: Typically around 0.032–0.045 W/m·K, depending on the selected insulation product
Key properties include continuous thermal insulation, naturally ventilated cavity, solar heat protection, moisture drainage and drying, weather protection, thermal-bridge control and fire compartmentation of the cavity
Thermal / Cooling Performance Provides high passive reduction of heat transfer through the opaque façade by combining thermal insulation, solar protection and removal of heat from the ventilated cavity
Actual performance depends on façade orientation, cladding properties, cavity ventilation, insulation level and thermal bridges
Applicability Criteria Suitable for buildings with significant façade solar exposure where improved thermal protection, moisture management and envelope durability are required
Adequate façade depth, structural support, cavity ventilation and fire-safety detailing must be available
Expected Service Life Cladding: Approximately 30–60+ years, depending on material
Substructure: Approximately 30–50 years
Joints, coatings, seals and other secondary components may require earlier maintenance or replacement
Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to: