Description

A ventilated façade is a rainscreen envelope system composed of an external cladding layer separated from the insulated backing wall by a continuous ventilated air cavity.

Solar radiation heats the outer cladding, while wind- and buoyancy-driven airflow within the cavity removes part of this heat before it reaches the primary building envelope. During heatwaves, the system can reduce heat transfer through the façade while protecting insulation and waterproofing layers.

Image

Default

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy

Implementation Guide

  • Assess façade orientation, solar exposure, wind and fire-safety requirements
  • Design a continuous ventilated cavity with unobstructed air inlets and outlets
  • Maintain continuous insulation and minimize thermal bridges through the substructure
  • Select durable cladding according to solar exposure and maintenance requirements
  • Provide drainage, cavity barriers and fire stops where required
  • Inspect joints, fixings and ventilation openings periodically

Benefits and Limitations

Benefits

  • Reduces solar heat transfer through the façade
  • Protects insulation and the primary envelope from weather exposure
  • Improves moisture management and envelope durability
  • Operates passively with low energy demand
  • Suitable for both new construction and retrofit

Limitations

  • Higher cost and façade depth than direct-applied systems
  • Performance depends on cavity continuity and cladding properties
  • Fire-safety detailing is critical
  • Substructures can create thermal bridges
  • Blocked or poorly ventilated cavities reduce performance

Parameter and data

Design: Rainscreen façade composed of external cladding, a ventilated air cavity and a continuous insulated backing wall. The cavity should allow effective airflow while maintaining drainage, fire compartmentation and protection of the primary façade

Materials and Components:

  • Ceramic or terracotta cladding
  • Fibre-cement panels
  • Metal panels
  • Stone
  • Timber
  • GRC or recycled composite panels
  • Mineral wool or bio-based insulation
  • Aluminium or steel substructure
  • Cavity barriers and fire stops
  • Insect mesh and drainage components where required

Application: External walls of residential, office, educational, healthcare and public buildings, for both new construction and retrofit projects

Technical Properties:

  • Insulation thickness: Typically 80–200 mm, depending on the required thermal performance
  • Ventilated cavity depth: Typically 40–100 mm, although larger cavities may be used according to façade geometry and ventilation requirements
  • Cladding thickness: Approximately 6–40 mm, depending on material and structural requirements
  • Overall system thickness: Approximately 150–350 mm
  • System weight: Approximately 30–120 kg/m², depending mainly on cladding material, substructure and insulation
  • Insulation thermal conductivity: Typically around 0.032–0.045 W/m·K, depending on the selected insulation product

Key properties include continuous thermal insulation, naturally ventilated cavity, solar heat protection, moisture drainage and drying, weather protection, thermal-bridge control and fire compartmentation of the cavity

Thermal / Cooling Performance: Provides high passive reduction of heat transfer through the opaque façade by combining thermal insulation, solar protection and removal of heat from the ventilated cavity. Actual performance depends on façade orientation, cladding properties, cavity ventilation, insulation level and thermal bridges

Operation: Passive, airflow is driven mainly by wind and stack effect

Advantages: Combines solar protection, thermal insulation, moisture management and weather protection within a durable passive façade system

Maintenance: Low–Medium: Periodic cleaning and inspection of cladding, fixings, joints, cavity openings, drainage and fire barriers

Environmental Impact: Medium–High: The additional cladding and substructure increase material use, although passive thermal protection and reduced cooling demand can provide operational benefits

Applicability Criteria: Suitable for buildings with significant façade solar exposure where improved thermal protection, moisture management and envelope durability are required. Adequate façade depth, structural support, cavity ventilation and fire-safety detailing must be available

Expected Service Life: Cladding: Approximately 30–60+ years, depending on material. Substructure: Approximately 30–50 years. Joints, coatings, seals and other secondary components may require earlier maintenance or replacement