Description

Non-return valves are installed in drainage and sewage pipes to prevent wastewater from flowing back into buildings when external sewer networks become overloaded during flood events.

The valve allows normal outward drainage but closes when reverse flow occurs, protecting basements, floor drains and low-level sanitary fixtures from sewage backflow, contamination and internal flooding.

Image

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy

Implementation Guide

  • Identify drainage connections and sanitary fixtures exposed to sewer backflow
  • Select a valve compatible with the drainage system, pipe diameter and expected surcharge conditions
  • Install the valve in an accessible inspection chamber or service location with correct flow orientation and watertight connections
  • Ensure access for cleaning, inspection and manual operation where applicable
  • Test valve operation after installation and periodically thereafter
  • Establish procedures to limit wastewater discharge from the building while the valve is closed

Benefits and Limitations

Benefits

  • Prevents sewage backflow and associated internal flooding
  • Reduces contamination and health risks in low-level spaces
  • Provides simple and relatively low-cost retrofit protection
  • Operates automatically in most systems without external power

Limitations

  • Protects only against sewer backflow and does not prevent other forms of floodwater ingress
  • Debris or sediment can prevent correct valve closure
  • Requires regular inspection, cleaning and functional testing
  • When closed, the protected drainage connection cannot normally discharge wastewater from the building
  • May provide insufficient protection if incorrectly sized, installed or maintained

Parameter and data

Design: Correct pipe sizing and flow orientation; watertight installation; accessible maintenance location; valve selected according to drainage type and expected sewer surcharge conditions

Materials and Components:

  • PVC, polymer or stainless-steel non-return valve
  • Sealing elements
  • Access or inspection chamber
  • Connection fittings
  • Manual locking device where applicable

Advantages: Simple and targeted protection that prevents sewage backflow and can be readily integrated into existing drainage systems

Maintenance: Medium: periodic cleaning, inspection and functional testing, particularly before flood-prone periods and after significant surcharge or flood events

Environmental Impact: Low: limited additional material use and no operational energy demand, while reducing the spread of contaminated wastewater inside buildings

Applicability Criteria: Suitable for basements and low-level drainage or sanitary installations exposed to sewer surcharge and backflow. Most effective where the protected drainage connections can be temporarily isolated while the valve is closed

Expected service life: 15–30 years, depending on valve type, wastewater conditions and maintenance. Seals and moving components may require earlier replacement