Fire compartments divide a building into fire-resisting zones using walls, floors, ceilings, doors, dampers and fire-stopping systems. They contain fire and smoke for a defined period, protecting escape routes and reducing internal fire spread.
For wildfire resilience, compartmentation limits the consequences if embers or external flames ignite one part of the building, helping prevent rapid involvement of the entire structure.
Image

Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:
Implementation Guide
- Define compartment boundaries and ratings from the project fire strategy
- Maintain continuity through walls, floors, ceilings, roof spaces and façade interfaces
- Protect doors, ducts, pipes, cables and joints with compatible tested systems
- Coordinate fire and smoke dampers with ventilation and smoke-control design
- Avoid concealed voids that bypass compartment lines
- Record fire-stopping systems for future inspection after service modifications
- Inspect fire doors, penetrations and boundaries throughout the building life
Benefits and Limitations
Benefits
- Limits internal fire and smoke spread
- Protects evacuation routes and critical areas
- Provides more time for evacuation and firefighting
- Reduces consequences of local ember-driven ignition
- Passive protection remains effective without power
Limitations
- Later service penetrations can compromise performance
- Retrofit can be invasive
- Doors and dampers require maintenance
- Does not extinguish fire
- Poorly coordinated façade/roof cavities can bypass compartmentation
Parameter and data
Application: Residential, office, commercial, educational, healthcare, industrial and public buildings
Construction Solutions: Fire-rated walls/floors, ceilings, doors, glazing, dampers and penetration fire stopping
Materials: Concrete, masonry, gypsum/calcium-silicate systems, mineral wool, fire-resistant glazing and tested sealants/collars
Fire Resistance: Typically EI/REI 30, 60, 90 or 120 minutes depending on use, height and national requirements
Penetrations: Every service penetration and movement joint must preserve the compartment classification
Expected Service Life: Primary construction 50+ years; doors, seals, dampers and fire stopping need periodic renewal
Maintenance: Inspect doors, seals, dampers, glazing and fire-stopping systems and review after service modifications
Indicative Regulatory References: EN 13501-2; EN 1364 / EN 1365; EN 1366 series; EN 1634; Regulation (EU) 2024/3110 (CPR) where applicable; national fire codes