Description

Flood-resilient drainage installations are designed to maintain effective water and wastewater evacuation during flood events while reducing sewer backflow, internal water accumulation and contamination risks.

The strategy combines adequate drainage capacity, network separation and isolation, backflow protection and, where required, emergency pumping to improve building functionality and accelerate post-flood recovery.

Image

Default

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy

Implementation Guide

  • Assess expected rainfall, flood conditions, sewer surcharge and drainage capacity
  • Size drainage systems according to the applicable design event and provide separate rainwater and wastewater networks where feasible
  • Install backflow-prevention devices at vulnerable sewer connections
  • Provide redundancy or emergency pumping where critical drainage functions must remain operational
  • Protect drainage equipment, inspection chambers and vulnerable connections against floodwater ingress and damage
  • Ensure pumps discharge to a safe outlet without causing re-flooding or transferring risk
  • Provide accessible inspection points and regularly inspect pipes, valves, chambers and pumps

Benefits and Limitations

Benefits

  • Reduces sewer backflow, internal flooding and wastewater contamination
  • Improves drainage performance during intense rainfall and flood events
  • Protects sanitation and critical drainage functions
  • Reduces building damage and supports faster post-flood recovery

Limitations

  • Retrofit of underground drainage networks can be complex and costly
  • Performance depends partly on the capacity and condition of the external drainage network
  • Pumps and active components depend on power supply and regular maintenance
  • Backflow devices can temporarily restrict wastewater discharge when closed
  • Major flood events may exceed the design capacity of the system

Parameter and data

Design: Drainage capacity sized according to the applicable design rainfall or flood event; rainwater and wastewater networks separated where feasible; vulnerable connections protected against backflow; emergency pumping and redundancy provided where required

Materials and Components:

  • Watertight PVC or HDPE drainage pipes
  • Backflow-prevention devices
  • Inspection chambers with protected covers
  • Sump or effluent pumps where required
  • Flow-control and isolation devices
  • Watertight joints and seals
  • Backup power for critical pumping systems

Advantages: Improves drainage capacity, reduces sewage backflow and internal water accumulation, and increases sanitation resilience during and after flood events

Maintenance: Medium: periodic inspection and cleaning of pipes and chambers, backflow-device testing, sediment removal and pump and backup-power testing where installed

Environmental Impact: Low–Medium: additional pipework, excavation and mechanical equipment create material and construction impacts, partially offset by reduced wastewater contamination and flood-related damage

Applicability Criteria: Suitable for flood-prone buildings with overloaded, outdated or backflow-sensitive drainage systems, particularly where intense rainfall or sewer surcharge can cause internal flooding. The specific configuration should be coordinated with the capacity and type of the external drainage network

Expected Service Life: 30–50+ years for main drainage pipework, depending on material, installation and exposure. Pumps, valves, seals, controls and backup-power components generally require earlier maintenance or replacement

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy