Description

Passive design uses building orientation, form, solar protection, natural ventilation, daylight control and thermal mass to reduce overheating without relying primarily on mechanical cooling.

During heatwaves, the strategy aims to limit unwanted solar gains, promote effective air movement and night-time heat release, and maintain useful daylight while minimizing glare and excessive heat transmission.

Image

Default

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy

Implementation Guide

  • Assess local climate, solar exposure, prevailing winds and urban obstructions
  • Orient and size openings to control solar gains and daylight
  • Provide cross-ventilation and stack-ventilation paths where appropriate
  • Prioritize external shading on highly exposed openings
  • Use thermal mass only where stored heat can be released effectively
  • Validate the strategy through solar, daylight and overheating simulations

Benefits and Limitations

Benefits

  • Can substantially reduce overheating and cooling demand
  • Requires little operational energy
  • Improves thermal comfort and daylight quality
  • Increases resilience during power interruptions
  • Compatible with most other heatwave adaptation measures

Limitations

  • Performance depends strongly on climate and building orientation
  • Requires appropriate occupant or automated operation
  • Retrofit opportunities may be limited by existing geometry
  • Natural ventilation may introduce noise, pollution, security or humidity issues
  • Thermal mass can increase overheating if stored heat cannot be released

Parameter and data

Design: Integrated passive strategy combining optimized orientation, controlled solar exposure, natural ventilation, daylight management and thermal mass. The design should prioritize reduction of heat gains before relying on mechanical cooling and should be verified under representative summer and heatwave conditions

Materials and Components: Depending on the selected strategy:

  • Operable windows
  • External shading devices
  • Louvers and balconies
  • Light-coloured internal finishes
  • High-performance envelope materials
  • Concrete, masonry or earthen thermal mass where appropriate
  • Courtyards, atria or ventilation shafts
  • Automated windows or controls where required

Application: New buildings and retrofits, including residential, educational, office, healthcare, cultural and mixed-use buildings

Technical Properties: Relevant design parameters include:

  • Window-to-wall ratio adapted to orientation
  • External shading geometry based on solar angles
  • Openings positioned to create effective airflow paths
  • Continuous insulation and airtightness
  • Thermal mass coordinated with night-time heat release
  • Daylight control and glare management

Specific numerical values should be defined according to climate and project geometry rather than applied universally

Thermal / Cooling Performance: Can substantially reduce cooling loads when orientation, external shading, natural ventilation and night purge are correctly combined. Actual performance is highly project- and climate-dependent and should be assessed through dynamic overheating simulation

Operation: Passive, user-controlled or hybrid, some strategies may operate entirely passively, while operable windows, blinds or ventilation openings can also be manually or automatically controlled through BMS logic

Advantages: Addresses overheating through the fundamental architecture of the building, reducing dependence on active cooling while simultaneously improving daylight, ventilation and resilience

Maintenance: Low: Periodic inspection of operable windows, shading devices, seals and controls

Environmental Impact: Low: Passive design can reduce operational energy and equipment requirements with limited additional material use. Environmental impacts depend mainly on the specific envelope and thermal-mass materials selected

Applicability Criteria: Applicable to both new construction and retrofit, but most effective when incorporated from early design stages. Particularly suitable where orientation, façade geometry, shading and ventilation paths can be optimized together. Natural ventilation strategies should consider outdoor temperature, noise, pollution, humidity, security and fire-safety constraints

Expected Service Life: Typically 50+ years, corresponding broadly to the primary building envelope and structural systems. Operable windows, shading mechanisms and automated controls may require earlier maintenance or replacement

Please download the PDF to have the information sent directly to your email address.

Healthcare Waste Insulation

Download pdf

Send download link to:

I have read and I accept the Privacy policy