Description
An ember-resistant roof is designed as a complete assembly to prevent wind-driven burning particles from entering concealed spaces or igniting vulnerable roof details. Embers can accumulate at eaves, valleys, roof-to-wall junctions, gutters and penetrations well ahead of the main wildfire front.
The measure therefore addresses roof covering, underlay, joints, ventilation openings, flashings, cavity closures and debris accumulation zones.
Image

Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:
Implementation Guide
- Specify a roof covering and complete build-up with suitable external-fire performance
- Close vulnerable gaps at ridges, eaves, valleys and roof-to-wall interfaces
- Use ember-resistant vents where roof or attic ventilation is required
- Provide non-combustible flashings around chimneys, rooflights and service penetrations
- Avoid exposed combustible membranes, foam edges or timber details at ember traps
- Design drainage details to minimise debris accumulation and facilitate cleaning
- Inspect before wildfire season and after storms
Benefits and Limitations
Benefits
- Addresses ember attack, a major wildfire ignition mechanism
- Provides passive protection without power
- Reduces hidden ignition in attics and roof cavities
- Can be incorporated during reroofing
- Works with non-combustible roof coverings and vegetation management
Limitations
- Local detailing failures can compromise the roof
- Ventilation requirements must still be met
- Debris accumulation can reintroduce ignition risk
- Complex existing roofs may be expensive to retrofit
- Roof covering classification alone does not guarantee ember resistance
Parameter and data
Application: Pitched and low-slope roofs in wildfire-prone areas
Construction Solutions: Fire-resistant roof covering, protected underlay, sealed eaves/ridges, non-combustible flashings and protected vents
Materials: Metal, slate, tile, mineral roofing, suitable membranes and fire-resistant sealants
External-Fire Performance: Roof classification to EN 13501-5 using the applicable test route; national rules determine the required class
Ember Entry Control: No unprotected openings into attic or concealed cavities
Debris Control: Geometry and maintenance access should limit leaves, needles and combustible residues
Expected Service Life: Typically 25-60+ years depending on roof material; seals and membranes may require earlier renewal
Maintenance: Seasonal cleaning and inspection of vents, flashings, seals and penetrations
Indicative Regulatory References: EN 13501-5; CEN/TS 1187 where applicable; Regulation (EU) 2024/3110 (CPR); national wildfire and roofing requirements
Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:

