Emergency exits are final doors or openings that allow occupants to leave a building or protected escape system and reach a place of safety. In wildfire-prone sites, the exit discharge must remain clear and should not lead directly into combustible landscaping, parked vehicles or likely flame paths.
The measure therefore includes both the exit assembly and the external discharge conditions immediately beyond it.
Image

Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:
Implementation Guide
- Provide the number and distribution of final exits required by occupant load and national rules
- Ensure exits are openable without keys or special knowledge during occupancy
- Use panic or emergency hardware where required
- Keep external discharge areas clear of combustible storage and dense vegetation
- Provide emergency lighting and visible exit signage
- Coordinate accessible egress and external assembly/safe-area planning
- Inspect locks, closers, thresholds and external clearances routinely
Benefits and Limitations
Benefits
- Provides the final transition from protected route to safety
- Reduces delay at the most critical evacuation point
- Can remain operable during power loss with simple mechanical hardware
- Supports fire-service access and reverse entry
- Improves reliability of the overall evacuation strategy
Limitations
- An exit is ineffective if the external discharge is unsafe
- Security measures can conflict with emergency release
- Vegetation or stored materials may obstruct exit areas
- Door hardware requires maintenance
- Public evacuation routes beyond the property may still be congested or closed
Parameter and data
Application: Final exits from stairs, corridors, public areas and parking
Door Hardware: Panic or emergency exit devices where required; compatible with fire/smoke rating where applicable
External Discharge: Clear, illuminated path to a place of safety or designated assembly area
Accessibility: Level or ramped discharge where required; opening forces and thresholds to accessibility rules
Expected Service Life: Door assemblies approximately 20-40 years; hardware and seals may require earlier replacement
Maintenance: Check free opening, security-release function, signage, lighting, obstructions and vegetation encroachment
Indicative Regulatory References: EN 1125; EN 179; EN 1634-1 where fire resistance is required; EN 1838; EN ISO 7010; national evacuation and accessibility rules