Description
Raised foundations elevate occupied building areas above the design flood level using piles, piers, raised slabs or elevated platforms. By physically separating habitable spaces and critical functions from ground-level flooding, the strategy provides a high level of long-term flood protection.
The space below the building can remain open or accommodate non-critical, flood-compatible uses, provided that floodwater can pass beneath without significant obstruction.
Image

Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to:
Implementation Guide
- Determine the design flood level and elevate occupied areas with an appropriate safety margin
- Design foundations and supports for structural loads, flood forces, scour, erosion and debris impact
- Minimize obstruction to floodwater flow beneath the building
- Locate critical services and utilities above the flood-risk zone or protect them appropriately
- Provide safe and accessible elevated entrances, stairs and ramps
- Inspect foundations, supports and exposed structural elements after major flood events
Benefits and Limitations
Benefits
- Provides a very high level of protection by avoiding direct flood exposure
- Significantly reduces structural, material and equipment damage
- Provides a passive and durable long-term resilience strategy
- Allows floodwater to pass beneath the building when appropriately designed
Limitations
- High construction cost and significant structural implications
- Difficult to implement in existing or dense urban buildings
- Elevated access can create accessibility and spatial challenges
- Foundations and supports remain exposed to scour, erosion and debris impact
- May be constrained by planning, height and urban-design requirements
Parameter and data
Design: Occupied areas elevated above the design flood level with an appropriate safety margin; foundations and structural supports designed for flood loads, scour and debris impact; open or flood-compatible space below the building with minimal obstruction to water flow
Materials and Components:
- Reinforced concrete piles, piers and slabs
- Steel or suitable timber structural systems
- Elevated platforms
- Foundation anchoring systems
- Scour and erosion protection
- Elevated stairs, ramps and entrances
Advantages: Provides robust and passive flood avoidance, minimizing direct exposure of occupied areas and substantially reducing damage and recovery requirements
Maintenance: Low–Medium: periodic inspection of foundations, structural supports, connections and access elements, with additional checks for scour, erosion, impact or structural damage following major flood events
Environmental Impact: Medium–High: additional foundations and structural materials can create significant embodied impacts, although long service life, reduced flood damage and limited obstruction to water flow can provide lifecycle benefits
Applicability Criteria: Suitable for new buildings in flood-prone coastal, river or pluvial-flood areas where sufficient elevation and open flow beneath the building can be accommodated. Less suitable for dense urban areas, existing buildings with major retrofit constraints or locations with strict building-height or accessibility limitations
Expected Service Life 50+ years for the main structural and foundation system, depending on structural design, materials, exposure conditions and maintenance. Access elements, protective components and finishes may require earlier renewal
Please download the PDF to have the information sent directly to your email address.
Healthcare Waste Insulation
Send download link to: